When it comes to the planning of a new building, there are standards in place for architects and specifiers to work towards to ensure constructions are as safe and sustainable as possible. These guidelines are building codes, and within these are energy codes which help direct builders on things like how much insulation to use and where to install it based on a building’s location depending on the climate.

The term continuous insulation means that the insulating material used covers the entire surface greatly reducing  the opportunity for thermal bridges, apart from in fasteners and service openings. By adding two-inch thick rigid insulation to the entire surface of your exterior wall, you’ll achieve continuous R-value. On the other hand, if you only provide blanket insulation between the studs of a wall, the R-value will be broken by the studs which don’t carry the same insulating value as the blanket insulating material.

Similarly, roof liner insulation that’s compressed by purlins through a metal roof system also cannot count as continuous insulation as it doesn’t feature a constant level of thickness throughout.

A lot of building codes include continuous insulation because it makes a positive impact on the energy efficiency by eliminating paths that allow heat to escape, known as thermal bridges. The requirements of such codes aim to increase energy efficiency, which in turn, reduces expensive heating and cooling costs across the lifespan of the building.

So, to answer the question, is continuous isolation required by code – there’s a number of factors to take into account.

Renovated buildings are not always required to meet the updated energy codes, however you should always check beforehand to ensure the build is code compliant.

The location of your project is another key consideration. In colder climates, for example, more insulation is required. Usually, countries will be split into zones to cater for the different average temperatures experiences, so to understand thoroughly if continuous insulation is required by code, you must identify the zone you’re building in.

You can do this via the US Department of Energy, which provides a regional map to help identify the different zones and energy codes.

For example, Kentucky US is entirely inside climate zone 4 which means that R15 continuous insulation is required by IECC 2021 for uninsulated wood-frame walls if no other non-continuous insulation is used.

When it comes to the different types of insulation, building codes don’t outline what this has to be to achieve the outlined R-value target, but in order to be most effective, insulation needs to be continuous. There’s a number of materials that can be used to create this continuous insulation barrier to surround the entire building envelope, including blanket, rigid, modular boards, blown-in and spray foam.

Implementing continuous insulation is all well and good if you’re creating a building with no access points (!), but as soon as the continuous insulation is disrupted by addition of windows, doors, cladding balconies, roofing fixtures, foundation columns etc. a thermal bridge is created.

Research has been conducted which reveals that thermal bridges can cause building conductive heat loss by more than 15%. This is dependent on the type of thermal bridge, along with the building type, climate and location, but the magnitude of thermal bridging should not be ignored.

To meet certain strict building codes, thermal bridges are simply not permitted, to significantly reduce heat loss – in turn reducing energy consumption. Keeping in mind the detrimental effects thermal bridges can have, they need to be combatted no matter what the project, to contribute towards higher efficiency and lower energy costs.

This can be done effectively and innovatively with the use of thermal breaks, which can create continuity in the thermal control layer, resulting in continuous insulation.

Research has been conducted which reveals that thermal bridges can cause building conductive heat loss by more than 15%. This is dependent on the type of thermal bridge, along with the building type, climate and location, but the magnitude of thermal bridging should not be ignored.

To meet certain strict building codes, thermal bridges are simply not permitted, to significantly reduce heat loss – in turn reducing energy consumption. Keeping in mind the detrimental effects thermal bridges can have, they need to be combatted no matter what the project, to contribute towards higher efficiency and lower energy costs.

This can be done effectively and innovatively with the use of thermal breaks, which can create continuity in the thermal control layer, resulting in continuous insulation.

Armatherm’s thermal break materials can be used to achieve continuous insulation at a number of connection points, from the very top of a project where roofing fixtures are attached, through the cladding and balconies, right down to the foundation columns. Anywhere there’s a penetration into the building envelope, creating an opportunity for a thermal bridge, a thermal break can be installed to ensure the continuation of the insulation and work towards efficient structures.

Other Articles
& Projects

Thermal break articles

Earn Credits Thermal Bridging Webinar

Thermal break articles

Armatherm upcoming events

Thermal break articles

Modular construction: improving energy efficiency

Thermal break articles

Armatherm’s 2024 Exhibitor Events

Thermal break articles

Thermal breaks specialists improve energy efficiency of luxury hotel by 60%

Thermal break articles

Thermal breaks are the missing links in continuous insulation

Thermal break articles

Ultra-high strength polyurethane can control heat loss through steel framing

Thermal break articles

Thermal bridging: Where does it occur

Thermal break articles

Why aren’t thermal breaks used more in construction projects?

Thermal break articles

How To Maximize The Efficiency of Cold Storage Facilities

Get in touch

Ready to talk about structural thermal breaks?

armatherm
Request a quote